? 网络小说排行榜,重生之毒妃 梅果 小说,yy玄幻小说排行榜完本

亚洲国产成人久久综合碰碰_亚州成一成人级毛片_BT天堂最新版在线_成人高清毛片视频_成年在线观看黄色_久久精品人妻综合AV_精品国产无码av最大网站_成网站在线观看人免费_日韩国产精品亚洲每日更新_免费国产一级看片

Laboratory syringe pump
Your location:home page > Products > Laboratory syringe pump > Laboratory syringe pump
  400-0602-365

Laboratory injection pump LSP02-2B
National Hotline:400-0602-365

LSP02-2B is mainly used in laboratories, excellent electromagnetic compatibility performance, ESD≥IV (IEC 61000-4-2), is widely used in chemical reaction injection experiments, electrostatic spinning, long-term animal drug injection experiments and other laboratory micro-injection experiments.

Flow range: 0.05μl/hr-150.56ml/min

Product introduction

LSP02-2B Laboratory injection pump is a perfusion/extraction type dual-channel injection pump, mainly used in the laboratory, with a full-size structure, excellent electromagnetic compatibility performance, ESD≥IV (IEC 61000-4-2). Multiple modes of operation enable it to adapt to the needs of a wide variety of applications in different fields. It has a very high control accuracy and a wide range of linear velocity, is the ideal high precision, small flow, low pulsation liquid transmission equipment; LSP02-2B injection pump is widely used in chemical reaction injection experiments, electrostatic spinning, long-term animal drug injection experiments and other laboratory microinjection experiments.

Functional characteristics

LSP02-2B Syringe inner diameter input function: You can select the syringe from the list or directly enter the syringe inner diameter

Man-machine interface friendly: large screen LCD display, digital knob in the film key to cooperate with the use, easy to operate, fast

Five working modes: perfusion/extraction/first perfusion and then extraction/first extraction and then perfusion/continuous operation

Power failure memory function: 1.EEPROM saves setting parameters. After powering on the PROM again, you do not need to reset parameters. 2. The system is powered off when running in flow mode. After the system is powered on again, the system can continue to run or stop according to the set parameters

Traffic jam protection function: When the propulsion mechanism of the injection pump is blocked during the working process, the injection pump will stop the work of the propulsion mechanism and give a siren alarm

485 communication bus can be connected with the host computer, through the background software to control it.

External control interface: provides input/output control functions

Liquid level calibration function: More accurate flow rate can be obtained through the calibration procedure

Syringe protection function: By adjusting the position of the limit block, the syringe can be prevented from being damaged

Technical index

Working mode: injection, extraction, injection before extraction, extraction after injection, continuous

Number of channels: 2

Stroke: 140mm

Stroke resolution: 0.156μm

Range of linear velocity: 5μm/min-130mm/min(flow rate = linear velocity × cross-sectional area of syringe)

Linear velocity adjustment resolution: 5μm/min

Stroke control accuracy: error ≤±0.5%(stroke ≥ 30% of stroke)

Rated linear thrust: > 180N

Syringe selection: The main manufacturer and type of syringe are built in for selection

Syringe customization: The syringe can be directly entered into the inner channel

Flow correction: More accurate fluid volume is obtained through the correction procedure

Operation parameter setting: injection amount, extraction liquid amount, injection time, extraction time

Display parameter selection: liquid volume, flow rate or linear velocity

Power failure memory: After power-on, you can decide whether to continue working as before

Status signal output: 2 OC gate signal output, used to indicate the start/stop and direction status

Control signal input: 2 start-stop control input terminals, 1 descending edge trigger signal control start-stop; One TTL level signal controls the start and stop

Communication interface: RS485

Dimensions: 280×250×140(mm)

Weight: 4.2kg

Power supply: AC 196V-240V/40W

Working environment temperature: 0℃-40℃

Working environment relative humidity: < 80%

Product size drawing

Other parameters

Injection pump model Applicable syringe size Syringe internal channel (mm) Reference flow range
LSP02-2B 10μl 0.50 0.001μL/min-0.0255mL/min
25μl 0.80 0.0025μL/min-0.0653mL/min
50μl 1.10 0.0048μL/min-0.1235mL/min
100μl 1.60 0.0101μL/min-0.2614mL/min
250μl 2.30 0.0208μL/min-0.5401mL/min
500μl 3.25 0.04151μL/min-1.0784mL/min
1ml 4.72 0.0875μL/min-2.2747mL/min
2ml 9.00 0.3181μL/min-8.2702mL/min
5ml 13.10 0.6739μL/min-17.522mL/min
10ml 16.60 1.0821μL/min-28.135mL/min
20ml 19.00 1.4176μL/min-36.859mL/min
30ml 23.00 2.0774μL/min-54.012mL/min
60ml 29.14 3.3346μL/min-86.699mL/min
100ml 34.9 4.7832μL/min-124.36mL/min
140ml 38.4 5.7907μL/min-150.56mL/min

 

Huiyu people bravely meet opportunities and challenges

Specializing in the research and development, production and sales of precision fluid transmission and processing equipment, focusing on creating high-quality, high-performance, and high-value products

If you are looking for related products or have any other questions, you can call our company's sales hotline at any time, or click the button on the right to consult and quote online!
Sales Hotline:400-0602-365
More contact information
Copyright ? Huiyu Weiye (Beijing) Fluid Equipment Co.,Ltd All Rights Reserved  Website production:sanjin.net  Record number:京ICP備17025788號-1