Main application: biological laboratory
Product introduction
LSP04-1A Laboratory injection pump is a four-channel single-push mode injection pump, mainly used in biological laboratories, with an integrated structure. Can be loaded with different specifications of syringes (sampler), LSP04-1A laboratory injection pump is suitable for high-precision, small flow liquid transfer.
Functional characteristics
LSP04-1A Syringe diameter input function: You can select the syringe from the list or directly enter the syringe diameter to determine the syringe
Working mode: single push mode
Easy to operate: large screen LCD display, digital knob and film keys are intuitive and easy to operate
Communication function: The 485 communication bus can be connected with the host computer, and it can be controlled through the background
External control interface: with input/output control function
Power failure memory function: 1. The EEPROM saves the Settings. After the EEPROM is powered on again, you do not need to reset the Settings. 2. The system is powered off when it is running in traffic mode. After the system is powered on, the system can continue to run or stop according to the set parameters
Liquid calibration function: More accurate flow rate can be obtained through the calibration procedure
Syringe protection function: By adjusting the position of the limit block, the syringe can be prevented from being damaged
Traffic jam protection function: When the propulsion mechanism of the injection pump is blocked during the working process, the injection pump will stop the work of the propulsion mechanism and emit a siren alarm
Technical index
Laboratory injection pump LSP04-1A Working mode: injection
Number of channels: 4
Stroke: ≤140mm
Stroke resolution: 0.156μm
Line speed range: 5μm/min-130mm/min(flow rate = line speed × internal cross-sectional area of syringe)
Line speed adjustment resolution: 5μm/min
Stroke control accuracy: error ≤±0.5%(stroke ≥ 30% of stroke)
Rated linear thrust: > 90N
Syringe selection: Built-in main manufacturers, main models of syringes for choice
Syringe customization: can directly input the inner channel of the syringe
Flow calibration: More accurate fluid volume is obtained through the calibration procedure
Operation parameter setting: dispensing fluid amount, injection time, etc
Display parameter selection: liquid volume, flow rate or line speed
Power failure memory: After power-on, you can decide whether to continue working as before
Status signal output: 2 OC gate signal output, used to indicate the start/stop and direction status
Control signal input: 2 start and stop control inputs, 1 falling edge trigger signal control start and stop; 1 TTL level signal control start and stop
Communication interface: RS485
Dimensions: 280×250×140(mm)
Weight: 4.4kg
Power supply: AC 90V-260V/20W
Working environment temperature: 0℃-40℃
Working environment relative humidity: < 80%
Injection pump model | Applicable syringe size | Applicable syringe length (mm) |
Reference flow range (μl/min-ml/min) |
LSP04-1A | 10μl | 0.50 | 0.001-0.0255 |
25μl | 0.80 | 0.0025-0.0653 | |
50μl | 1.10 | 0.0048-0.1235 | |
100μl | 1.60 | 0.0101-0.2614 | |
250μl | 2.30 | 0.0208-0.5401 | |
500μl | 3.25 | 0.0415-1.0784 | |
1ml | 4.72 | 0.0875-2.2747 | |
2ml | 9.00 | 0.3181-8.2702 | |
5ml | 13.10 | 0.6739-17.522 | |
10ml | 16.60 | 1.0821-28.135 |