Introduction to Pump Head
Used in high-precision distribution and small flow filling
Phase compensation design
The special tube assembly effectively reduces the pulsation and improves the filling accuracy. Can be adapted to 25# tube
Max flow rate:1760ml/min
1.Low pulse ,high-presion
2.Specialized in high-precision dispensing and small flow rate filling
3.PPS housing ,can stand acid ,alkali,and orangic solvent
Flow curve
Dimensions
Technical Data Sheet
Model | Wheel material | Number of rollers | Shell material | Range of rotation | Applicable hose specifications | Reference flow (ml/min) | Repeatability error |
Weight (kg) |
DMD15-1A | SUS304 | 6 | Shell: aluminum alloy Upper pressure block: POM |
≤600 | 2×13# | ≤80 | ≤±1% | 0.9 |
2×13# | ≤160 | |||||||
2×14# | ≤300 | |||||||
DMD15-2A | PPS | 2×19# | ≤620 | 0.5 | ||||
2×16# | ≤960 | |||||||
2×25# | ≤1760 |